Microsoft trials hydrogen-powered data centers

The software giant has begun testing hydrogen fuel cells as a back-up power source at one of its U.S. data centers. A 250 kW pilot system successfully powered part of the facility for 48 hours and the company is now eyeing 3 MW systems to replace back-up diesel generators.

U.S. software giant Microsoft this week announced the successful trial of a hydrogen fuel cell system to power one of its data centers. The company said the 250 kW pilot project provided proof of concept and, beyond back-up power, Microsoft said it has a much bigger vision of playing a leading role in the growth of a ‘hydrogen economy.’

Working with Utah-based developer Power Innovations, Microsoft began testing the pilot system in September and achieved a milestone last month when the fuel cell unit powered a data center for 48 hours. The 250 kW system is sufficient to power a full row of 10 server racks at a Microsoft Azure data center. “It is the largest computer back-up power system that we know, that is running on hydrogen, and it has run the longest continuous test,” said Mark Monroe, who works on Microsoft’s team for data center advanced development.

Monroe’s team now wants a 3 MW fuel cell system, to match the size of the diesel generators currently providing back-up power for data centers.

Hydrogen stored in tanks at the Power Innovations lab near Salt Lake City. It was used to power servers at a Microsoft data center for 48 hours straight.

Image: Power Innoations

Microsoft wants to eliminate diesel from its operations by 2030 and, given recent cost reductions in fuel cell technology, hydrogen offers an increasingly viable route. Another target involves the company’s data centers reaching 99.999% – “five nines” – service availability.

“We don’t use the diesel generators very much,” said Monroe. “We start them up once a month to make sure they run and give them a load test once a year to make sure we can transfer load to them correctly, but, on average, they cover a power outage less than one time per year.”

While the Microsoft data center the hydrogen system was used on also deploys batteries to cover the time needed to fire up a diesel generator, longer-term back-up solutions are necessary. The company is also evaluating other solutions but the generation profile of a fuel cell appears a good match to its requirements. “An automotive fuel cell has the reaction time like a diesel generator does,” said Monroe. “It can turn on quickly. It can be ready for a full load within seconds. You can floor it, let it off, let it idle.”

Hydrogen economy

Rather than sitting idle most of the time, as diesel generators do, Microsoft sees a role for hydrogen infrastructure beyond providing back-up power. “All of that infrastructure represents an opportunity for Microsoft to play a role in what will surely be a more dynamic kind of overall energy optimization framework that the world will be deploying over the coming years,” said Lucas Joppa, the company’s chief environmental officer.

Joppa said there is a lot of work to be done to scale-up the generation, transport and distribution of hydrogen for such an economy to develop and Microsoft has said it is involved in conversations about how it could spur such developments.

“What if you could take all of these assets the data center has and integrate them into the grid in a way that helps to further accelerate decarbonization of the grid more broadly, rather than just a point solution for the data center itself,” said Brian Janous, general manager of Microsoft’s team for datacenter energy and sustainability strategy. “That’s where I think all of this gets interesting.”